Overview

Reactive distillation carries out a chemical reaction and a separation in the same column. Here the equilibrium-limited liquid-phase reaction
A+B⇌C+D
takes place in the middle section of a distillation column. Because the lightest product (C) is continuously drawn off at the top and the heaviest product (D) at the bottom, the reaction is pushed toward completion. Nearly pure C and D can therefore be obtained from an A/B feed in a single unit, with no separate reactor, no downstream separation train and no recycle of unreacted A and B.
This notebook builds the complete set of steady-state material balances for the column, solves them simultaneously, and plots the liquid and vapor composition profiles of A, B, C and D versus stage number. Curves are red (A), blue (B), green (C) and magenta (D). The shaded bands mark the column sections: rectifying (light green), reactive (light blue) and stripping (light red).

Problem statement

◼
  • Components and volatilities. The relative volatilities are given with respect to the heaviest component D:
    α
    CD
    =7
    ,
    α
    AD
    =4
    and
    α
    BD
    =3
    (and
    α
    DD
    =1
    ). The volatility order is therefore C > A > B > D.
  • ◼
  • Reaction.
    A+B⇌C+D
    occurs in the liquid phase with rate
    r=k
    x
    A
    x
    B
    -
    x
    C
    x
    D
    K
    eq
    and equilibrium constant
    K
    eq
    =0.25
    .
  • ◼
  • Column. There are 17 equilibrium stages, numbered from the top, plus a total condenser (labelled stage 0 in the code, so
    x
    i,0
    is the distillate and reflux composition). Stage 17 is the reboiler.
  • ◼
  • Sections. Rectifying zone: stages 1 to 5 (no reaction). Reactive zone: stages 6 to 14. Stripping zone: stages 15 to 17 (no reaction). The feed enters on stage 10, inside the reactive zone.
  • ◼
  • Feed.
    F=100
    kmol/h of saturated liquid containing 50 mol % A and 50 mol % B (no C or D).
  • ◼
  • Specified operating variables. Damköhler number
    Da
    , reflux ratio
    R
    and reboil ratio
    s
    (see below). The default values are
    Da=5
    ,
    R=9
    and
    s=10
    .
  • Modeling assumptions

    ◼
  • Steady state, with every stage an equilibrium stage (vapor and liquid leaving a stage are in equilibrium).
  • ◼
  • Constant molal overflow (CMO): the vapor flow
    V
    is the same on every stage, the liquid flow is
    L
    above the feed stage and
    L′=L+F
    below it (the feed is a saturated liquid).
  • ◼
  • Heat effects (heats of reaction and mixing) are neglected, which is what makes CMO valid.
  • ◼
  • Ideal vapor-liquid equilibrium described by constant relative volatilities.
  • ◼
  • The reaction occurs only in the liquid phase and only on the reactive stages. The liquid holdup
    H
    and the rate constant
    k
    are the same on every reactive stage.
  • ◼
  • Total condenser: the reflux has the same composition as the distillate. The reboiler is treated as an equilibrium stage.
  • Dimensionless parameters

    The three numbers below can be changed in the first input cell. They are the only inputs you normally need to touch.
    ◼
  • Damköhler number
    Da=
    H/L
    1/k
    : the ratio of the liquid residence time per stage (
    H/L
    ) to the characteristic reaction time (
    1/k
    ). Here
    H
    is the liquid holdup on a stage,
    k
    the reaction rate constant and
    L
    the liquid flow rate in the top section of the column. In the balances the reaction term of a reactive stage is
    Hkr=DaLr
    .
  • ◼
  • Reflux ratio
    R=L/Dist
    : liquid returned to the column divided by the distillate flow.
  • ◼
  • Reboil ratio
    s=V/B
    : vapor generated in the reboiler divided by the bottoms flow. (In the code and equations,
    Dist
    and
    B
    denote the distillate and bottoms flow rates; the italic
    B
    is the flow, the upright B is the component.)
  • Limiting cases: for
    Da=0
    no reaction takes place and no C or D appears in the column. For very large
    Da
    the reactive stages approach reaction equilibrium, i.e.
    r=0
    .

    Model equations

    Index
    n
    is the stage number and
    i
    is the component, with
    x
    i,n
    and
    y
    i,n
    the liquid and vapor mole fractions leaving stage
    n
    . The stoichiometric coefficients are
    ν
    A
    =
    ν
    B
    =-1
    and
    ν
    C
    =
    ν
    D
    =+1
    . Only
    x
    A
    ,
    x
    B
    and
    x
    C
    are independent unknowns, because
    x
    D
    =1-
    x
    A
    -
    x
    B
    -
    x
    C
    .
    Vapor-liquid equilibrium (relative volatilities with respect to D):
    y
    i,n
    =
    α
    i,D
    x
    i,n
    α
    A,D
    x
    A,n
    +
    α
    B,D
    x
    B,n
    +
    α
    C,D
    x
    C,n
    +
    x
    D,n
    Dimensionless reaction rate on stage
    n
    (the rate constant
    k
    is absorbed in
    Da
    ):
    r
    n
    =
    x
    A,n
    x
    B,n
    -
    x
    C,n
    x
    D,n
    K
    eq
    Component balance on a reactive stage (stages 6 to 9 use the liquid flow
    L
    , stages 11 to 14 use
    L′
    ; non-reactive stages simply omit the last term):
    V(
    y
    i,n+1
    -
    y
    i,n
    )+L(
    x
    i,n-1
    -
    x
    i,n
    )+
    ν
    i
    DaL
    r
    n
    =0
    Feed stage (stage 10, with feed composition
    x
    F,i
    ):
    V(
    y
    i,11
    -
    y
    i,10
    )+L
    x
    i,9
    -L′
    x
    i,10
    +
    ν
    i
    DaL
    r
    10
    +F
    x
    F,i
    =0
    Total condenser and reboiler:
    V
    y
    i,1
    =(L+Dist)
    x
    i,0
    V
    y
    i,17
    +B
    x
    i,17
    =L′
    x
    i,16
    Flow relations:
    V=Dist+L
    ,
    R=L/Dist
    ,
    L′=L+F
    ,
    Dist+B=F
    and
    s=V/B
    .

    Solution method

    The unknowns are the five flows
    V
    ,
    B
    ,
    L′
    ,
    Dist
    and
    L
    , plus
    x
    A
    ,
    x
    B
    and
    x
    C
    on stages 0 to 17 (54 values), i.e. 59 unknowns in total. The balances above give exactly 59 nonlinear algebraic equations, which are solved all at once with FindRoot (a Newton-type method). The result is stored in the list of replacement rules sol, and the plots evaluate the profiles with /. sol.
    Notes: FindRoot needs reasonable starting values, supplied in the solver cell. If you change
    Da
    ,
    R
    or
    s
    substantially and the solver fails or returns an unphysical solution, adjust the initial guesses. The solver call is wrapped in Quiet, so warning messages are suppressed. The loose AccuracyGoal of 1 combined with Quiet makes it worth glancing at the plots (compositions must lie between 0 and 1) after every change.
    To run the notebook, choose Evaluation > Evaluate Notebook. The cells depend on each other and must be evaluated in the order shown.

    Operating parameters

    In[]:=
    (*Operatingparameters:editthesevaluesandre-evaluatethenotebook*)​​​​Da=5;(*Damköhlernumber,Da=Hk/L:liquidresidencetimeperstagedividedbythereactiontime.​​Da=0meansnoreaction;averylargeDaapproachesreactionequilibriumonthereactivestages*)​​R=9;(*refluxratio,R=L/Dist(refluxflow/distillateflow)*)​​s=10;(*reboilratio,s=V/B(vaporfromthereboiler/bottomsflow)*)

    Chemistry and thermodynamic data

    In[]:=
    (*ReactionandVLEdata​​Componentsarenumbered1=A,2=B,3=C,4=D.​​Thevariablesx1[n],x2[n],x3[n](liquidmolefractionsonstagen)aretheunknowns​​solvedforlater;x4[n]isobtainedfromthesummationconstraintbelow.*)​​​​Keq=0.25;(*equilibriumconstantofA+B<=>C+D*)​​​​(*Dimensionlessreactionrateonstagei:r=xAxB-xCxD/Keq.​​TherateconstantkisnotneededherebecauseitiscontainedinDa.​​SetDelayed(:=)isusedsothattherateisre-evaluatedeachtimewiththecurrentxvalues.*)​​rate[i_]:=x1[i]x2[i]-x3[i]x4[i]/Keq;​​​​(*RelativevolatilitieswithrespecttocomponentD(theleastvolatile,alpha_DD=1)*)​​α34=7;(*alpha_CD*)​​α14=4;(*alpha_AD*)​​α24=3;(*alpha_BD*)​​

    Vapor-liquid equilibrium and composition closure

    In[]:=
    (*Vapormolefractionsinequilibriumwiththeliquidleavingstagei​​y_j=alpha_j4x_j/(alpha_14x_1+alpha_24x_2+alpha_34x_3+x_4),withalpha_44=1*)​​​​y1[i_]:=α14x1[i]/(α14x1[i]+α24x2[i]+α34x3[i]+x4[i]);(*A*)​​y2[i_]:=α24x2[i]/(α14x1[i]+α24x2[i]+α34x3[i]+x4[i]);(*B*)​​y3[i_]:=α34x3[i]/(α14x1[i]+α24x2[i]+α34x3[i]+x4[i]);(*C*)​​y4[i_]:=x4[i]/(α14x1[i]+α24x2[i]+α34x3[i]+x4[i]);(*D*)
    In[]:=
    (*Summationconstraint:themolefractionsoneverystageaddupto1,​​sothefourthone(D)isnotanindependentunknown*)​​x4[i_]:=1-x1[i]-x2[i]-x3[i];

    Feed specification

    In[]:=
    (*Feed:saturatedliquid,100kmol/h,equimolarinAandB*)​​​​xf1=0.5;(*molefractionofAinthefeed*)​​xf2=0.5;(*molefractionofBinthefeed*)​​xf3=0;(*molefractionofCinthefeed(Disthenalso0,sincethefractionssumto1)*)​​F=100;(*feedflowrate,kmol/h*)

    Solving the steady-state balances

    In[]:=

    Results

    With the default values the specifications give
    R+1=s
    , so the flow relations force
    Dist=B=50
    kmol/h, with
    V=500
    ,
    L=450
    and
    L′=550
    kmol/h. Half of the feed moles therefore leave as distillate and half as bottoms, as expected from the 1:1 stoichiometry.

    Liquid composition profiles

    Liquid mole fractions of A (red), B (blue), C (green) and D (magenta) on stages 0 to 17. The bands show the rectifying zone (light green), the reactive zone (light blue) and the stripping zone (light red).
    In[]:=
    (*Liquidcompositionprofilesversusstagenumber*)​​​​Show[​​ListPlot[​​{​​Table[{i,x1[i]},{i,0,17}]/.sol,(*A:replacex1[i]byitssolvedvalueusingtherulesinsol*)​​Table[{i,x2[i]},{i,0,17}]/.sol,(*B*)​​Table[{i,x3[i]},{i,0,17}]/.sol,(*C*)​​Table[{i,x4[i]},{i,0,17}]/.sol(*D,computedfrom1-x1-x2-x3*)​​},​​GridLines->{Table[i,{i,1,18,1}],Table[i,{i,0,1,0.1}]},(*oneverticallineperstage,horizontallinesevery0.1*)​​ImageSize->400{1,1},​​Joined->True,(*connectthepointsofeachcurve*)​​PlotRange->{{0,17},{0,1}},​​PlotStyle->{{Thick,Red},{Thick,Blue},{Thick,Green},{Thick,Magenta}},(*A,B,C,D*)​​Frame->True,​​FrameLabel->{"stage number","liquid composition"}​​],​​(*Shadedbandsmarkingthecolumnsections,drawnontopoftheplot*)​​Graphics[{​​Blue,Opacity[0.25],Rectangle[{6,0},{15,1}],(*reactivezone*)​​Green,Opacity[0.25],Rectangle[{0,0},{6,1}],(*rectifyingzone*)​​Red,Opacity[0.25],Rectangle[{15,0},{17,1}](*strippingzone*)​​}]​​]
    How to read the plot. C (green) is enriched toward the top and approaches 0.99 mole fraction in the distillate, while D (magenta) is enriched toward the bottom and reaches about 0.99 in the reboiler. The reactants A (red) and B (blue) are concentrated in the middle of the column, where they peak inside the reactive zone and are consumed; they drop to about 1 mol % or less at both ends. Both products leave almost pure, and the overall conversion of A and B exceeds 98 % (values quoted for the default parameters).

    Vapor composition profiles

    Conclusions

    For the default parameters, reactive distillation delivers nearly pure C overhead and nearly pure D at the bottom, with conversions close to 100 %. The process is simpler than the conventional alternative of a reactor followed by separation units with recycle of unreacted A and B.